Image: DEVI5year
warranty
warranty
DEVIpipeheat™ 10 V2 is a self-limiting heating cable for frost protection of pipes, installed on the outside of water pipes. Its output increases or decreases according to the ambient temperature. The range includes drum cable, cable with cold lead and no mains plug, and cable with cold lead and mains plug.
Features and applications
- Cut to length on site
- Ready-made lengths
- Small cable size
- Safety: all self-limiting heating cables must be over-temperature protected by a thermostat (their output decreases but never reaches zero) and protected by an RCD with a maximum trip current of 30 mA.
Specifications
| Nominal voltage | 230 V~ |
|---|---|
| Nominal output tolerance | 10 W/m @ 10 °C (8.5–13.5 W/m @ 10 °C) |
| Max. permissible use temperature, powered | 65 °C |
| Max. permissible use temperature, unpowered | 65 °C |
| Min. use temperature | -5 °C |
| Heating cable dimensions | 7.8 x 5.3 mm |
| Outer sheath | Blue, TPE |
| Min. screen coverage | 100% aluminium foil |
| Max. resistance, protective braid | 18.2 Ω/km |
| Bending Ø, min. | 25 mm (Ø to the inside of the cable) |
| Cold lead with plug | 2 m, 3 x 0.75 mm², Schuko plug (type AU-003) |
| Max. length on pipe, 10 A C-curve breaker @ 10 °C | 100 m (60 m inside the water pipe) |
| Max. length @ 0 °C / -20 °C | 96 m / 77 m |
| IP class | IPX7 |
Options and product codes
| Product code | Product name | Output @ 230 V |
|---|---|---|
| 98300016 | DEVIpipeheat™ 10 | 10 W/m |
Data from the Heat Zone 2026 product catalogue. Check the current DEVI data sheet for your exact product code before installation. Need the PDF data sheet? Call 1800 519 654 or email info@heatzone.com.au.
Related products
More outdoor & frost protection
Image: DEVIOutdoor cable · 30 W/m
DEVIsnow 30T
UV-stable twin-conductor cable for embedding in concrete, asphalt or under pavers to melt snow and ice.
- Driveways and ramps
- Steps and paths
Image: DEVISelf-limiting cable · 18 W/m @ 10 °C
DEVIiceguard
Self-limiting cable for roofs, gutters and downpipes. Output rises as it gets colder, and it cuts to length on site.
- Gutters and downpipes
- Roof edges and valleys